Buy 960702A20V3001 from Leybold in South Africa

BRAND Leybold
Product 960702A20V3001
Description rotary vane vacuum pump
Internal code IMP4708596
Custom code 84141025
Technical specification SV300 B WATER ATEX CAT.2 INT SPECIFIC 1 LA vane vacuum pump, single-stage, with oil seal, cooled by water with exhaust filters and integrated oil recovery, certified according to directive 2014/34/EU of 26 February 2014 for: - internal category 2 for class gases up to IIB + H2 temperature class 180°C at 50Hz and T3 (200°C) at 60Hz (according to CEI 60079- 20-1:2010) no external Atex classification, for ambient temperature from 10 to 50°C. Suction gas temperature: less than 60°C if pressure Suction rate greater than 10 mbar, and less than 100°C if pressure less than 10 mbar. - marking II (i) 2 G b IIB 180°C at 50Hz and T3 at 60Hz (10°C <Ta<50°C) X. - The pump is equipped with: - a suction check valve - a permanent air ballast 15 m3/h with thread 1/2 G for neutral gas supply, - a PT100 temperature probe (4-wire) intended for monitoring the vacuum generator, (stop temperature setting: 105°C). - Port for measuring crankcase pressure. - static FKM seals, shaft seals with protection, - with drain valve and oil filter, - a 2nd brand plate delivered separately. Pump without yellow metals on the oil circuit. Final total pressure with air ballast <= 1.5 mbar, nominal flow: 280 m3/h at 50Hz, nominal flow: 340 m3/h at 60Hz, effective flow: 240 m3/h at 50Hz, effective flow: 290 m3/h at 60Hz, CEI three-phase motor 7.5 kW, 50Hz/8.5 kW, 60Hz 220-230-240/380-400-415 V 50Hz and 440-460V 60Hz. The motor is equipped with CTP probes on all 3 windings. Suction and discharge ports: 2'G LEYBONOL LVO211 Synthetic Ester Oil, min. Oil quantity /max: 8 5.5/11.5 ltr, use of LVO300 synthetic PAO oil possible. net weight approx: 240kg Materials in contact with gases: Steel, cast iron, aluminium, aluminium, FKM, PTFE, Glass, GFK, Polyamide 6.6, Filtration materials (Polymer, paper). The pump is delivered with operating and maintenance instructions trilingual (English, German, French). Follow the instructions for use and maintenance of the pump. Atex use restrictions: - Limiting the pressure in the oil pan at 0.5 bars relative to the atmosphere, (~1.5 abs) - Generator temperature monitoring, maximum temperature 105°C. - This pump should not be used in Atex applications other than solvent washing machine. - The air ballast must be supplied in such a way as to That no Atex mixture can appear in the pump. - The temperature of the air ballast supply and the intake of air from the engine must not exceed 40°C. - The thermostatic valve must be adjusted so as to obtain an operating temperature of between 80° and 90° C. The repair or maintenance of vacuum pumps or ATEX components must be made according to the EN60079-19 standard governing maintenance and repair of ATEX equipment. Additional information is available in the document Y26/300600566/000

         Discover the superior quality and performance of the Leybold 960702A20V3001 with Impexron GMBH in South Africa . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.

The 960702A20V3001 is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.

Key Features of 960702A20V3001 :

  • High Performance: Engineered to deliver exceptional results.
  • Durable Construction: Built with high-quality materials for long-lasting use.
  • Innovative Design: Incorporates the latest technology for enhanced efficiency.
  • Cost-Effective: Offers great value for money with competitive pricing.

At Impexron GMBH , we offer the 960702A20V3001 at competitive prices and with the fastest delivery times across South Africa . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.

Why Choose Impexron GMBH ?

  • Expert Assistance: Get help from our knowledgeable team for all your product-related questions.
  • Competitive Prices: We offer some of the best prices in the market.
  • Fast Delivery: Benefit from our efficient delivery network for quick turnaround times.
  • Customer Satisfaction: Our commitment to customer service ensures a great buying experience.

Get Your Quote Today! Ready to enhance your operations with the 960702A20V3001 ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.     

Important Notice: While we supply Leybold products, Impexron GMBH is not an authorized distributor. All rights are reserved by the manufacturers and their official partners. 

More products of Leybold

P/N: 960875, Type: SOGEVAC SV750 B

Rotary vane vacuum pump

830061V3300

TURBOVAC 350 I/ix

800100V0003

TURBO. POWER INTEGRA

800102V0002

Power cable - EURO plug - 3 m

800134V0021

Mounting kit TURBOVAC DN 100 CF

800110V0021

Start-stop switch TURBOVAC i

800136V0005

Air cooling TURBOVAC 350-450 i - radial

800132V0021

Protective grille DN 100 CF (3.2 mm)

11256

TRIVAC D8B

12092

IONIVAC ITR 90

ES83943

Copper gasket for CF flanges

12455

Connection cable type C

85414

Adsorption trap DN 16 ISO-KF

88504

reducer ISO-KF

83637

CF crosspiece

ES83945

Copper gasket for CF flanges

83615

CF T-piece

230681V01

GRAPHIX TWO

Contact us for request